Specification:
Automatic mode: program start ~ 4.2V charging stop voltage for charging, charging current is less than the stop current for 30 seconds, the first charging is completed ~ quiescent (not charging and not discharging) ~ discharge according to the stop voltage setting, the load voltage is lower than the stop voltage for 10 seconds, discharging is completed ~ quiescent (not charging and not discharging) ~ charging with the re-charging voltage as the stop voltage, re-charging voltage is set to 4.2V, charging current is less than the stop current for 30 seconds, the program is set to stop voltage. When the recharge voltage is set to 4.2V, the charging current is less than the stopping current for 30 seconds, the programme ends (when the recharge voltage is not equal to 4.2V, the battery voltage reaches the recharge voltage, the programme ends), the recharging is completed, the programme ends, and the operation of the automatic mode is completed.
Charging mode: program start ~ charging voltage is set to 4.2V, charging current is less than the stop current for 30 seconds, the programme ends(charging voltage is not equal to 4.2V, the battery voltage reaches the charging voltage, the programme ends) ~ charging is complete.
Discharge mode: programme start ~ load voltage lower than the stop voltage for 10 seconds, programme end ~ discharge complete