Hydraforce Part Number: SV08-30M-0-N-00
Solenoid Operated Cartridge Selector Valve
When de-energized, the SV08-30M allows flow from 2 to 1 while blocking flow at 3.
When energized, the cartridge's spool shifts to open from 3 to 2, while blocking flow out 1.
Operation of Manual Override Option:
To override, push button in, twist counterclockwise 180°.
The internal spring will push the button out. In this position, the valve may be only partially shifted.
To assure full override shift, pull the button out to its fullest extension and hold it in this position.
To return to normal operation, push button in, twist clockwise 180°, and release. Override will be
detented in this position.
Features:
4 GPM max Flow
3000 PSI Rated
Manual Override
Fits VC08-3 Cavity
Uses Size 08 (1/2" Hole) Solenoids