Contactor
Product number
SW200-176
Coil rated voltage (DC V) 6V, 12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V, 150V
Contact circuit rated load current (A) 500A
Main contact voltage drop under 100A load ≯80mV
At (20±5)℃, cooling pull-in action voltage (V) ≯70%
At (20±5)℃, cooling release action voltage (V) ≯30%,≮5%
The allowable fluctuation range of coil voltage is ±20%
Power-on action time 10 milliseconds
Power-off release time 40 milliseconds
Contact opening maximum bounce time 3 milliseconds
Insulation resistance 20MΩ
Dielectric strength 50Hz/60Hz 1000VAC 1minute
Maximum switching capacity of main contact (power on 5ms) 1500A/5ms at 48V DC
Coil power consumption (W) 13-20
Electrical life: 20,000 times
Mechanical life: 1 million times
Working specification: continuous or intermittent
Contact type: Normally open
Contact Material AgCdO(12)
Auxiliary contact rated load (optional) 2A/48VDC, 5A/24VDC
Auxiliary contact type (optional) one normally open and one normally closed
Use environment:
Ambient temperature -25~+70℃
Relative humidity +20℃ 98%
Vibration frequency at fixed position: 3G, 1~50Hz, amplitude: 0.5mm
Impact (60~100) times/min, acceleration ≤4g
Altitude 2000m
Installation direction Any
Protection grade IP40 (according to GB14048.4, equivalent to IEC60947)