12 Samples Processed: Each gas flow rate can be adjusted separately to meet the different needs of users. At the same time, it overcomes the weakness of different gas flow rate of the non-adjustable nitrogen blower.Each air needle channel in the distribution room can be used in combination or separately, and each air needle can be switched on and off separately. The height of the distribution room can be adjusted as required.
Self-balance Suspension Lifting System: The water bath nitrogen blowing instrument has a unique self-balance suspension lifting system, clever design, so that the height adjustment of the distribution room is more flexible, truly achieve one-hand operation.
Qualitative Materials: The module for storing the sample is made of high quality aviation aluminum. The parts that may contact with the solvent are made of stainless steel material, alloy aluminum and plastic spraying surface, long service life and easy to clean.
Ф 0.59" Test Tube: The general standard heating block specification is the pore size of 0.59" (15mm), and users with special specifications can book their special pore size and form in advance.
Heating Tube: The heating tube design makes the heating process more uniform, and can control the temperature well, avoid the local overheating phenomenon that may be caused by direct heating, and ensure the uniform heating and protection of the sample, suitable for a variety of laboratory operations requiring precise temperature control.
وصف
Nitrogen concentrator is mainly used for enrichment of large-volume sample or preparation (such as drug screening, hormone analysis, liquid phase, and mass spectrometry in the analysis of sample preparation). Working principle: the nitrogen into the heated surface of the sample and make the solvent t evaporate and separated rapidly, thereby reaching the sample enrichment purpose without oxygen, keep the sample purer. Nitrogen concentrator instrument can concentrated dozens of samples simultaneously, saving time and high efficient, instead of rotary evaporation instrument. Product Parameters
Product model: 12 place
Voltage: 110V
Power: 600W
Number of samples processed: 12
Test tube size: Ф 0.59"(15mm)
Nitrogen consumption: 330 ml/min / Sample (adjustable)
Gas flow indicator: 0-15L/min
Standard number of heating blocks: One test tube rack
Temperature control accuracy:±1℃
Temperature control range: Room temperature-100℃
Temperature control mode: Digital display control temperature
Package size: 16.1"*16.1"*11.8" (41cm*41cm*30cm)
Net weight/Gross weight: 13.6lbs(6.15kg)/15.8lbs(7.17kg)