Search

LineSplitter - Conductor Splitter Without Cable Stripping, 120V

KWD 26

Weight
0.6 kg
1 +

Special Features

  • Conductor splitting without cable stripping
  • Mains voltage (L-N, L-PE, N-PE)
  • Leakage current on protective conductor
  • Measurement of leakage current under RCD mode (L-N)
  • Phase current

Description

HT Instruments LineSplitter - Conductor Splitter Without Cable Stripping Conductor Splitter Without Cable Stripping Standard measurement section and a x10 multiplier section for use with higher ranged clamp meters Used to make voltage checks safely with standard multimeter probes LINESPLITTER was designed by HT to carry out splitting among active Phase, Neutral and PE conductors on single-phase installations powered by 2- or 3-pole cord cables up to 16A absorption. You will be able to take immediate measurements of current by means of clamps/DMMs which would be otherwise impossible without stripping the cable to get access to individual conductors . This unit is is powered by 120V mains supply through built-in shuko plug. LINESPLITTER complies with IEC/EN61010-1 standards for electronic equipment. It can be used for CURRENT and AC VOLTAGE measurements on CAT II 120V earthed installations with max load current of 15A. Ergonomics The line splitter has connection wires to the wall and the device under test to eliminate stresses on the wall outlet and provide easy access for measuring instruments. The only splitter that measures leakage current from either the "Line to Neutral" or "Line to Ground".