8 قطعة تيار مستمر 5 فولت وحدة التتابع 1 قناة التتابع التبديل التتابع المجلس مع Optocoupler العزلة دعم عالية أو منخفضة المستوى الزناد

KWD 4

1 +

مميزات خاصة

  • Wide Application:The relay board works well with ARM /PIC /AVR /MCU/Raspberry/CNC machine/ PS4 etc.
  • 5V Relay Module: Working Voltage: DC 5V; Maximum Load: AC 250V/10A, DC 30V/10A; Trigger Current of Opto-Isolator: 5mA
  • Fault-Tolerant Design: Fault Tolerant Design, Even if the Control Line is Broken, the Relay will not Operate;All Interfaces of Relay can be Wired Out Through the Terminals Directly,Normally Open and Normally Closed
  • Optocoupler Isolation:1 Channel Relay Board use Optocoupler Isolation that has Strong Driving Ability and Stable Performance ,The Isolation Circuit Prevent Damages to I / O Port by Relay Switch Current
  • Jumper Design: The Relay Module has a Jumper That You Can Set Rather the Unit State Changes with High or Low Signal. Has Screw Terminals for Relay (NC,C,NO) and for Input; Coil +, Coil - and Trigger.

وصف

A module description: 1, the module uses genuine high-quality relay, the maximum load of the normally open interface: AC 250V/10A, DC 30V/10A; 2, using patch optocoupler isolation, strong driving ability, stable performance; trigger current 5mA; 3, the module working voltage is available in 5V, 12V, 24V; 4. The module can be triggered by a jumper to set a high level or a low level; 5, fault-tolerant design, even if the control line is broken, the relay will not move; 6, power indicator (green), relay status indicator (red) 7, the interface design is user-friendly, all interfaces can be directly connected through the terminal block, very convenient 8, module size: 50mm * 26mm * 18.5mm (length * width * height) 9, with 4 fixing bolt holes, hole 3.1mm, spacing 44.5mm*20.5mm Two module interface: 1. DC+: Connect the positive pole of the power supply (the voltage is selected according to the relay, and there are 5V, 12V and 24V options) 2, DC-: connected to the negative pole of the power supply 3, IN: can control the relay to pull high or low Relay output: 1. NO: The relay normally open interface, the relay is suspended before the suction, and the short is connected with COM after the suction. 2, COM: relay common interface 3. NC: The relay normally closes the interface, and the relay is shorted to COM before the suction is closed. High and low trigger selection: 1. When the jumper is shorted to LOW, it is triggered by low level; 2. When the jumper is shorted to high, it is triggered by a high level. Third, technical parameters: Relay version Quiescent current Maximum current Trigger current Trigger voltage (low) High 5V 5mA 190mA 2-4mA 0-1.5V 2.5-5V 12V 5mA 80mA 2-4mA 0-4V 4.5-12V 24V 5mA 50mA 2-4mA 0-8V 8.5-24V

منتجات شبيهه


{"error":"\u062e\u0637\u0623","cart_limit":"\u0644\u062f\u064a\u0643 \u0627\u0644\u0643\u062b\u064a\u0631 \u0645\u0646 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0641\u064a \u0633\u0644\u0629 \u0627\u0644\u062a\u0633\u0648\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643.","prod_limit":"\u0644\u0627 \u064a\u0645\u0643\u0646\u0643 \u0625\u0636\u0627\u0641\u0629 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c"}