Main technical indicators and precautions:
1. Environmental conditions for the use of low pressure solenoid valve inlet valves
1.1 Altitude does not exceed 2500 meters
1.2 ambient temperature is (0-40 ℃ )/(32-104℉)
1.3 The relative humidity of air is below 95% (temperature is 25 ℃/77℉)
2. Type and rated technical parameters
2.1 Type: Guided (one-way) solenoid valve (also known as non-filled pilot valve action or solenoid valve)
2.2 Rated voltage: DC 12V DC 24V AC110V AC220V
2.3 Rated current: 12V-300MA/24V-220MA
2.4 Working methods: short-term quota system (ie, intermittent period work system)
2.5 Insulation class: Class E insulation
2.6 Use fluid: (0-55 ℃) /(32-131)℉water
2.7 Water pressure: 0.02-0.8Mpa
2.8 Water flow characteristics:
When the water pressure is 0.02Mpa,flow is more than 5L/min;
When the water pressure is .01Mpa,flow is more than 11L/min;
When the water pressure is 0.3Mpa,flow is more than 18L/min;
When the water pressure is 0.8Mpa,flow is more than 32L/min/
2.9 Life: more than 100,000 times