Product Parameters
Supply Voltage: VDD: 1.71V-3.6V (Core Power), VDDIO: 1.2V-3.6V (Logic Level)
Communication: I²C (up to 3.4 MHz) / SPI (up to 10 MHz)
Measurement Ranges:
: ppb-level VOC/VSC/CO/H₂ Detection
Temperature: -40°C to +85°C (±0.5°C Accuracy @ 0-65°C)
Humidity: 0-100% RH (±3% Accuracy @ 25°C)
Pressure: 300-1100 hPa (±0.6 hPa Accuracy)
Power Consumption:
1.1µA @ 1Hz Temp/Humidity Mode
90µA Ultra-Low Power (ULP) Mode
3.9mA Standard Scan Mode
Package: 3.0 × 3.0 × 0.93 mm LGA-8 (Lead-Free, RoHS Compliant)
ESD Protection: ≥8 kV Contact Discharge
Pin Functions
VDD: Core Power Input (1.71V-3.6V), Connect to DC Positive
VDDIO: I/O Level Shifter Power (1.2V-3.6V)
GND: Power Ground
SCL: I²C Clock Line
SDA: I²C Data Line
CS: SPI Chip Select (Active Low)
SDI/SDO: SPI Data Input/Output
SCK: SPI Clock Line
FAQ
1.
Connection Recognition Failure
Ensure I²C/SPI mode jumpers are correctly set (default I²C). For SPI, solder CS pin and configure logic level (VDDIO must match host MCU voltage, e.g., 3.3V).
2.
Abnormal Readings (e.g., VOC Drift)
Enable heating layer via set Heater(320°C, 100ms)to stabilize measurements. Calibrate using BME AI-Studio for specific patterns.
3.
Higher Power Consumption Than Specified
Activate ULP mode via iaqUpdate()function. Disable unused sensors (e.g., pressure) and reduce I²C/SPI clock frequency to ≤1MHz.