Input Voltage Range (DC+AC peak-peak value):X20 attenuation ratio: ≤ 140Vpp, about 50Vrms or DC
Input Voltage Range (DC+AC peak-peak value):X50 attenuation ratio: ≤ 350Vpp, about 125Vrms or DC
Input Voltage Range (DC+AC peak-peak value):X200 attenuation ratio: ≤ 1400Vpp, about 500Vrms or DC
Maximum Input Voltage:Maximum differential voltage: 1400V(DC+AC peak-peak value) or 500Vrms Voltage to ground at the input terminal:600Vrms
Input Impedance:Differential: 4MΩ/1.2pF;Single-ended and to ground: 2MΩ/2.3pF
Output Impedance:50Ω
Rise Time:14ns
Accessories:1 User's Guide;1 dual-BNC coaxial cable;1 Dual-banana plug silicon cable;1 AC power adapter;1 Safety IC clip;1 Safety alligator clip
Description
RP1000D series high voltage differential probe can convert high differential input voltage to low voltage and display the waveforms on the oscilloscope. Its working frequency is up to 25MHz(RP1025D), 50MHz (RP1050D) and 100MHz (RP1100D) and it is rather suitable for large electricity test and R&D.