vibration sensor
RelaysFeatures: -Strong anti-interference ability stable performance simple circuit and high precision; the outer for shell adopts a guide rail casing which is easy to install and beautiful in appearance. -And has the function of adjustment and digital filtering -Standard 2 relay output function contact capacity 7A/250VAC. Specifications: Power supply: working voltage AC90260V; power consumption is less than 2W Measuring accuracy: 0.5%FS1 Measuring range -40110 Display character height: 0.36 inches high brightness red LED Use environment: -1060 (relative humidity below 80%) Dimensions: 110*36 *60 (mm) Sensor Length: 1.5m Package included: 1* Din Rail Thermostat 1* Sensor ------- Code Table: TY1: Relay 1 output alarm type 0: Upper limit alarm temperature AL1 the relay is closed (AL1-HY1) the relay is off. 1: Lower limit alarm temperature AL1 the relay is closed (AL1+HY1) the relay is off. 2: Upper and lower limit alarm. Temperature AL1 the relay is closed HY1 the relay is closed. AL1: Relay 1 action value -40.0130.0 HY1: Relay 1 difference -40.0130.0 TY2: Relay 2 output alarm type 0: Upper limit alarm temperature AL2 the relay is closed (AL2-HY2) the relay is off. 1: Lower limit alarm temperature AL2 the relay is closed (AL2+HY2) the relay is off. 2: Upper and lower limit alarm. Temperature AL2 the relay is closed HY2 the relay is closed. AL2: Relay 2 action value -40.0130.0 HY2: Relay 2 difference -40.0130.0 SEC: Relay action delay value 0-999 seconds When the relay AL1 or AL2 reaches the operating conditions it will delay the action for SEC seconds. When it is 0 there is no delay. LC: Temperature deviation correction value -20.020.0 (display value = measurement value + LC)