Motor Type: for DC Motor
Input Voltage: 5V - 48V DC
Load Current: Max 10A
RF Frequency: 433MHz
Range: The open field is more than 50 to 168ft
Receiver Sensitivity: -114dBm
Max Number of Controllers: 32
Product Name: Forward Reverse Switch
How to use self locking mode?
1. Press remote control "up" button once, the motor rotates positively; press remote "stop" button, the motor stops rotating.
2. Press remote control "down" button once, the motor will rotate in the reverse direction; press remote control "stop" button, the motor will stop rotating.
How to use momentary mode?
1. Press remote control "up" button once, the motor rotates positively once, release "up" button, the motor stops rotating;
2. Press remote control "up" button again, the motor rotates positively once again, release "up" button, the motor stops rotating.
3. Press and hold the "up" button, the motor rotates continuously.
4. The same principle applies to the "down" button.
How to change to self locking mode
Step 1: Press and hold the programming button on top of the switch, the light will come on, the light will flash 1 time after about 2 seconds,do not release continue to press and hold the button, after about 2 seconds the light will flash 2 times then release the button
Step 2: Press "up" button of the remote control once, then press "down" button of the remote control again.
Step 3: The light on the top of the switch will flash 3 times, programming is complete.
How to change to momentary mode?
Step 1: Press and hold the programming button on top of the switch, the light will come on, the light will flash 1 time after about 2 seconds,then release the button
Step 2: Press "up" button of the remote control once, then press "down" button of the remote control again.
Step 3: The light on the top of the switch will flash 3 times, programming is complete.