BY7 AC SPD 20KA-40KA 3P ~ 320V with Crack-proof Buckle UL Surge Protector Protection Arrester in Kuwait BY7 AC SPD 20KA-40KA 3P ~ 320V with Crack-proof Buckle UL Surge Protector Protection Arrester in Kuwait BY7 AC SPD 20KA-40KA 3P ~ 320V with Crack-proof Buckle UL Surge Protector Protection Arrester in Kuwait BY7 AC SPD 20KA-40KA 3P ~ 320V with Crack-proof Buckle UL Surge Protector Protection Arrester in Kuwait

BY7 AC SPD 20KA-40KA 3P ~ 320V with Crack-proof Buckle UL Surge Protector Protection Arrester

KWD 39

Color3
SizeAC320V
1 +

Special Features

  • Gas Tube Arrestors

Description

Gas Tube Arrestors
1-BY7 Series Introduction
BY7surge protector with reliable voltage protection level and the safety of overload characteristics, drainage turn surge current capability is strong. protection for ac low voltage power distribution system.BY7surge protector with high-energy MOV, fast response speed, safe and reliable protection.Products comply with GB18802.1-2011 (IEC61643-1.2005), IEC61643-11.2011 standard.
2-Technical Date
TYPE: BY7
Protection Class: C
Working Voltage: ~220V
Max.Continuous Operating Voltage (Uc): ~320V
Nominal Discharge Current (8/20s) (In): 20KA
Max. Discharge Current (8/20s) (Imax.): 40KA
IP Protection Level: IP20
Combiner type:1+0, 2+0, 3+0, 4+0, 1+1, 2+1, 3+1
alarmmodule,FScommunication module: OPTIONAL
indicate deterioration: green(normal),red(malfunction)
Material of Outer Shell: Flame retardant material
3-Main applications
Low Voltage SPD
Very different devices, from both a technological and usage viewpoint, are designated by this term. Low voltage SPDs are modular to be easily installed inside LV switchboards.There are also SPDs adaptable to power sockets, but these devices have a low discharge capacity.
4-Principle
SPD is designed to limit transient overvoltages of atmospheric origin and divert current waves to earth, so as to limit the amplitude of this overvoltage to a value that is not hazardous for the electrical installation and electric switchgear and controlgear.
5-SPD Eliminates Overvoltages
in common mode, between phase and neutral or earth;
in differential mode, between phase and neutral.
In the event of an overvoltage exceeding the operating threshold, the SPD
conducts the energy to earth, in common mode;
distributes the energy to the other live conductors, in differential mod
===================================
6-Common Characteristics
Uc: Maximum continuous operating voltage
This is the A.C. or D.C. voltage above which the SPD becomes active. This value is chosen according to the rated voltage and the system earthing arrangement.
Up: Voltage protection level (at In)
This is the maximum voltage across the terminals of the SPD when it is active. This voltage is reached when the current flowing in the SPD is equal to In. The voltage protection level chosen must be below the overvoltage withstand capability of the loads. In the event of strokes, the voltage across the terminals of the SPD generally remains less than Up.
In: Nominal discharge current
This is the peak value of a current of 8/20 µs waveform that the SPD is capable of discharging minimum 19 times
Why is In important?
In corresponds to a nominal discharge current that a SPD can withstand at least 19 times: a higher value of In means a longer life for the SPD, so it is strongly recommended to chose higher values than the minimum imposed value of 5 kA.
Maximum discharge curren
This is the peak value of a current of 8/20 µs waveform that the SPD is capable of discharging once.
==========
High-concerned chemical : None
Type : SPD
Model Number : BY7
COLOR : Green
Type : Surge protection device
Voltage : ~320V
Max. Discharge Current (8/20s) (Imax.) : 40kA
Nominal Discharge Current (8/20s) (In) : 20kA
Combiner type : 3+0
Protection Level : IP20
Chip : High energy MOV

Related Items


{"error":"Error","cart_limit":"You have too many items in your cart.","prod_limit":"You cannot add any more of this item"}