الاجهزه الالكترونيات الامريكية قد تحتاج الى محمول فولت من ١١٠ الى ٢٢٠.قد تحتاج إلى محول كهرباء
مميزات خاصة
[ULTRA RELIABLE INDUSTRIAL PERFORMANCE] Engineered for demanding environments, this rugged RS485 repeater delivers stable with complete photoelectric isolation between all ports. Achieves blistering fast transmission speeds up to 115.2Kbps while resisting electromagnetic interference in factory settings. Industrial-grade components ensure 24/7 operation.
[TOTAL PORT ISOLATION TECHNOLOGY] Features advanced DC/DC power isolation between all 4 ports to eliminate ground loops and electrical noise. The isolated power design prevents voltage spikes from damaging connected equipment while maintaining signal integrity across long cable runs up to 2500 meters.
[MASSIVE NETWORK EXPANSION CAPACITY] Each of the 4 isolated channels supports connection of 128 devices, enabling huge industrial networks. for building automation, warehouse management systems, and factory floor where multiple PLCs and sensors need reliable connectivity.
[INTELLIGENT DATA FLOW MANAGEMENT] Smart directional control technology automatically manages data transmission without configuration. Self-adjusting signal processing maintains optimal speeds while preventing data collisions in multi-drop RS485 networks.
[CIRCUIT PROTECTION] Incorporates multiple mechanisms including ±15KV ESD shielding, 600W TVS suppression, and 2.5KV port-to-port isolation. These protections safeguard against strikes, power surges, and electrostatic discharge in harsh industrial electrical environments.
وصف
Item Type: Repeater
Compatibility: Compatible with RS-232, RS-485TIA/EIA standards
Working Voltage: DC: 9-24V
Rated Power: 0.5-1.2W
Input Interface: 1 RS-232/1 RS-485
Output Interface: 4 RS-485
Load Capacity: 128 nodes per interface
Communication Distance: 2500 meters shielded wire or twisted pair wire per interface
Communication Rate: 300bps-115.2Kbps
Installation Method: 35mm rail installation, 4-hole installation on the back plate
Structure Size: Approx. 115 x 90 x 40mm / 4.5 x 3.5 x 1.6in
Working : -30℃ to 70℃ relative humidity>95%RH
Wiring Notes:
1. 485 communication line must use shielded twisted pair, preferably multiple strands for spare, the longest is not more than 2500 meters.
2. The wiring should be as far away as possible from high-voltage wires, not parallel to power lines, and not to be bundled together.
3. 485 bus must be a hand-in-hand bus structure, and resolutely eliminate star connection and bifurcation connection.
4. If there are more than 30 controllers or the cable length is greater than 500 meters, it is recommended to use a 485 repeater.
5. The AC-powered equipment and the chassis must be grounded and well grounded.
6. Connect the GND ground of all 485 devices with shielded wires.
Requirements For Wire Selection Using RS-485 Bus For Communication:
Use 2-core shielded twisted pair cable
Copper, wire diameter 0.5~0.75 square millimeter,
Impedance 38~88Ω/km,
Capacitive resistance 30~50nF/km,
2-core shielded twisted-pair cable with a twisting distance of 20 mm (if the line distance is not more than 500 meters, the line standard can be appropriately reduced, but it must be a twisted pair)
Signal Common Ground:
1. All devices on the same network segment must have a unified signal ground to avoid common mode interference.
2. For centralized power supply, directly connect the DC negative poles of all power supplies on