بحث

بيت / YTUANXSALOUE / أدوات ومعدات المختبر
YTUANXSALOUE مختبر ماصة، ماصة كهربائية متعددة الوظائف ذات ثماني قنوات ماصة مختبر 0.5-10ul/10-100ul/30-300ul(30-300ul) in Kuwait

YTUANXSALOUE مختبر ماصة، ماصة كهربائية متعددة الوظائف ذات ثماني قنوات ماصة مختبر 0.5-10ul/10-100ul/30-300ul(30-300ul)

KWD 447

اللونبيانكو
مقاس30-300ul
1 +

مميزات خاصة

  • Functionality: Rotatable dispensing head for easy pipetting
  • Application: 8 and 12 channel pipettes for 96-well plates
  • Strong: Composite tip cone ensures high sealing performance
  • Convenience: Separate piston and tip cone assembly for easy repair and maintenance
  • fixed volume single channel micropipette for precise liquid handling in laboratories.

وصف

Tips for pipetting:
Before pipetting, make sure the pipette, tip and liquid are at the same temperature;
Keep the tip tightly attached;
When aspirating, place the tip only a few millimeters into the liquid;
Before aspirating liquid, pre-rinse the tip by filling and emptying it 5 times.
This is especially important when dispensing liquids with a different viscosity and density than water;
Always control the button movement with your thumb to ensure consistency;
When pipetting at a temperature different from the ambient temperature, pre-rinse the tip several times before use;
Choose 30%-100% of the maximum capacity of the tip to achieve accurate pipetting, with 50% being the best recommendation;
Hold the pipette vertically when aspirating and hold the tip slightly against the wall of the container when dispensing;
Technical Parameters
Volume Range: 0.5-10 µL
Increment: 0.1 µL
Test Volume (µL):
10 µL: Accuracy Error 1.50% (0.15 µL), Precision Error 1.50% (0.15 µL)
5 µL: Accuracy Error 2.50% (0.125 µL), Precision Error 2.50% (0.125 µL)
1 µL: Accuracy Error 4.00% (0.04 µL), Precision Error 4.00% (0.04 µL)
Volume Range: 5-50 µL
Increment: 0.5 µL
Test Volume (µL):
50 µL: Accuracy Error 1.00% (0.5 µL), Precision Error 0.50% (0.25 µL)
25 µL: Accuracy Error 1.50% (0.375 µL), Precision Error 1.00% (0.25 µL)
5 µL: Accuracy Error 3.00% (0.15 µL), Precision Error 2.00% (0.1 µL)
Volume Range: 50-300 µL
Increment: 5 µL
Test Volume (µL):
300 µL: Accuracy Error 0.70% (2.1 µL), Precision Error 0.25% (0.75 µL)
150 µL: Accuracy Error 1.00% (1.5 µL), Precision Error 0.50% (0.75 µL)
50 µL: Accuracy Error 1.50% (0.75 µL), Precision Error 0.80% (0.4 µL)
Contenu de l'emballage : 1 * pipette

منتجات شبيهه


{"error":"\u062e\u0637\u0623","cart_limit":"\u0644\u062f\u064a\u0643 \u0627\u0644\u0643\u062b\u064a\u0631 \u0645\u0646 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0641\u064a \u0633\u0644\u0629 \u0627\u0644\u062a\u0633\u0648\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643.","prod_limit":"\u0644\u0627 \u064a\u0645\u0643\u0646\u0643 \u0625\u0636\u0627\u0641\u0629 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c"}