Features:
Slim and Low profile (41mm)
Fanless and conduction-cooled design
Withstand 300VAC surge input for 5 seconds
Built-in active PFC function
-30~+70℃working temperature
Output voltage and constant current level programmable
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in remote ON-OFF control
DC OK active signal
Operating altitude up to 5000 meter
LED indicator for power on
5 years warranty
General Specification:
AC input voltage range:90~264VAC 250~370VDC
AC inrush current (Typ.):Cold start :20A/115VAC 40A/230VAC
Overload protection:105~120% rated output power Protection type : Constant current limiting with delay shutdown after 3 seconds,re-power on to recover
Short circuit protection:Protection type :Constant current limiting with delay shutdown after 3 seconds,re-power on to recover
Over voltage protection:12V:14.5~16V, 24V:29~33V, 36V:43.5~49V, 48V:59~66V Protection type :Shut down O/P voltage,re-power on to recover
Over temperature protection:Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
Setup, rise, hold up time:1000ms,50ms/230VAC/115VAC at full load; 12ms/115VAC,230VAC
Withstand voltage:I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.25KVAC
Working temperature:-30~+70℃(Refer to “Derating Curve)
Safety standards:UL62368-1,TUV EN62368-1,EAC TP TC 004 approved; design refer to EN61558-1, EN60335-1
EMC standards:EN55032 (CISPR32) Class B ;EN61000-3-2,3;EN61000-4-2,3,4,6,8,11,EN61000-6-2
Dimension (LxWxH):240×115×41mm