Relays
Contactor
Product number
ZJW400A-H
Coil rated voltage (DC V) 6V 12V 24V 36V 48V 60V 72V 84V 120V 150V
Contact circuit rated load current (A) 400A
Main contact voltage drop under 100A load ≯80mV
At (20±5)℃ cooling pull-in action voltage (V) ≯70%
At (20±5)℃ cooling release action voltage (V) ≯30% ≮5%
The allowable fluctuation range of coil voltage is ±20%
Power-on action time 10 milliseconds
Power-off release time 40 milliseconds
Contact opening maximum bounce time 3 milliseconds
Insulation resistance 20MΩ
Dielectric strength 50Hz/60Hz 1000VAC 1minute
Maximum switching capacity of main contact (power on 5ms) 1500A/5ms at 48V DC
Coil power consumption (W) 13-20
Electrical life: 20 000 times
Mechanical life: 1 million times
Working specification: continuous or intermittent
Contact type: one normally open and one normally closed
Contact Material AgCdO(12)
Auxiliary contact rated load (optional) 2A/48VDC 5A/24VDC
Normally closed to normally open action time 14 milliseconds
Normally open to normally closed action time 8 milliseconds
Use environment:
Ambient temperature -25~+70℃
Relative humidity +20℃ 98%
Vibration frequency at fixed position: 3G 1~50Hz amplitude: 0.5mm
Impact (60~100) times/min acceleration ≤4g
Altitude 2000m
Installation direction Any