Current Sense
2. DC bidirectional current measurement.
3. DC bidirectional power measurement.
4. DC bidirectional cumulative energy measurement.
5. High voltage alarm flashing function.
6. Low voltage alarm flashing function.
7. High current alarm flashing function.
8. Low battery alarm flashing function.
16. Ultra-wide power supply voltage range: DC5-90V.
2. LCD panel and buttons
3. Button Usage Instructions
Backlight control:
In the standby display state, short press the " " key to turn on or off the screen backlight. The backlight state is automatically saved when the power is turned off.
Clear current:
In the standby display, press and hold the " " button for about three seconds to clear the current. (Note: the load must be no-load when clearing, otherwise it will be inaccurate)
Clean electricity:
In the standby display, press and hold the " " button for about three seconds to clear the power.
1 “AH XXX.X” battery rated capacity setting menu.
2 "FU XXX.X" full power automatic voltage compensation menu
environment.
3. “HU XXX.X” high pressure alarm setting menu.
4 “LU XXX.X” low voltage alarm setting menu.
5 “HA XXX.X” high current alarm setting menu.
Current test range
0-100A
0-200A
0-400A
Current resolution
0.1A
0.1A
0.2A
Power supply voltage range
DC5-90V
Voltage test range
DC0-300V
Voltage resolution
0.1 volt
Capacity test range
0-999AH
Power test range
0-999 kW
energy test site
0-999 kWh
Panel mounting slot dimensions
76.0mm*39.5mm
Sensor hole diameter
20 mm
Working current
When backlight is on: 10MA.
When backlight is off: 4mA.
The meter has three wires, as follows:
1. Connect the black wire to the negative terminal of the battery.
2. Connect the red wire to the positive pole of the power supply.
3 yellow wire to the positive pole of the battery
When the voltage range is DC5-90V, the red and yellow wires are connected in parallel to the positive pole of the battery. As shown below:
When the measuring voltage range exceeds DC5-90V, another power supply should be found for the coulombmeter. As follows:
7. Precautions for use
1When the battery is discharging, Coulomb displays a positive current. When the battery is charging, Coulomb displays a negative current. If not, the sensor is in the wrong direction. Please reverse the sensor direction.
1 * Sensor
1 * 15cm sensor extension cable
1 * 3p power cord
Batteries Included: No
Model: DC 0-300V
DIY Supplies:
Size: 80*42mm
Working temperature: -10℃-65℃
Accuracy level: High
Power supply: DC
Display Type: Numbers only