بحث

بيت / EC Buying / الضوابط والمؤشرات
2PCS 12V MELAY MODULE 1-channel 30a مع وحدة ترحيل عزل Optocoupler 5MA ذات مستوى مرتفع ومنخفض. in Kuwait 2PCS 12V MELAY MODULE 1-channel 30a مع وحدة ترحيل عزل Optocoupler 5MA ذات مستوى مرتفع ومنخفض. in Kuwait 2PCS 12V MELAY MODULE 1-channel 30a مع وحدة ترحيل عزل Optocoupler 5MA ذات مستوى مرتفع ومنخفض. in Kuwait 2PCS 12V MELAY MODULE 1-channel 30a مع وحدة ترحيل عزل Optocoupler 5MA ذات مستوى مرتفع ومنخفض. in Kuwait 2PCS 12V MELAY MODULE 1-channel 30a مع وحدة ترحيل عزل Optocoupler 5MA ذات مستوى مرتفع ومنخفض. in Kuwait

2PCS 12V MELAY MODULE 1-channel 30a مع وحدة ترحيل عزل Optocoupler 5MA ذات مستوى مرتفع ومنخفض.

KWD 4

ماركة
EC Buying
وزن
29 g
1 +

مميزات خاصة

  • Static current: 5mA; Maximum current: 80mA; Trigger current: 2-4mA
  • Trigger voltage (low): 0-4V; Trigger voltage (high): 4.5-12V
  • Module size: 50mm * 33mm * 24mm (length * width * height)
  • There are 4 fixed bolt holes with a diameter of 3.1mm and a spacing of 44 5mm*27.5mm
  • Double-sided PCB boards, with comprehensive layout considerations and stable performance

وصف

The 1-channel 12V relay module series uses patch optocouplers for isolation, with stable performance and user-friendly design. It can be triggered by high-level or low-level signals, and only requires 5mA current to drive a relay with a control capability of 30A. The module adopts power relays, small packaged optocouplers, high-power high-voltage transistors, red and green signal indicator lights, double-sided PCB boards, with comprehensive layout and stable performance. It is suitable for various single-chip microcontroller controls and can be widely used in various power control applications.

12V version
Static current: 5mA
Maximum current: 80mA
Trigger current: 2-4mA
Trigger voltage (low): 0-4V
Trigger voltage (high): 4.5-12V

Pin definition
1. DC+: Module DC power supply positive pole (trigger terminal voltage positive pole)
2. DC -: Module DC power supply negative pole (trigger terminal voltage negative pole)
3. IN: Signal trigger terminal (default trigger voltage is the same as the power supply)
4. JD+: Positive terminal voltage of relay control terminal
5. JD -: Negative terminal voltage of relay control terminal
6. Short circuit DC+and JD+with jumper caps, and short circuit DC - and JD - with jumper caps to trigger The voltage at the terminal is the same as that at the relay control terminal
7. Selection of high and low level triggering methods, as shown in the figure, when the jumper is connected to the L terminal, the IN terminal
Triggered at a low level, triggered at a high level when connected to the H terminal
8. Normally closed end (NC): Relay normally closed end
9. Common Terminal (COM): Relay Common Terminal
10. Constant start (NO): Relay constant start

منتجات شبيهه


{"error":"\u062e\u0637\u0623","cart_limit":"\u0644\u062f\u064a\u0643 \u0627\u0644\u0643\u062b\u064a\u0631 \u0645\u0646 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0641\u064a \u0633\u0644\u0629 \u0627\u0644\u062a\u0633\u0648\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643.","prod_limit":"\u0644\u0627 \u064a\u0645\u0643\u0646\u0643 \u0625\u0636\u0627\u0641\u0629 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c"}