Signal Isolator:Input and output,ultra-thin, intelligent and isolated safety net.
HIGH-QUALITY PERFORMANCE: The DC conditioner has good cold resistance, excellent insulation, resistance, leakage resistance, vibration resistance, and Molded coatings are used to protect circuit boards and related equipment from environmental attack
EASY INSTALLATION: 35MM Standard guide rail installation, installation does not take up space, strong versatility. DC24V power supply provides isolated energy distribution for field transmitters, which is safer and more energy-saving
Widely Used: Signal converters are widely used in industrial equipment, such as large motors, medical equipment,Power system,mechanical equipment,etc.
Product Material and Safety: Current signal conditioner is made of high quality electronic components with high precision,High precision, low temperature drift
وصف
1PC Intelligent Universal Temperature Transmitter Signal Isolator and Distributor PT100/TC/V/mV/mA to 4-20mA converter
Functions And Features:
Integrated intelligent temperature transmitter, isolator and distributor.
Isolation of the four "input-output1-output2-power".
Software nonlinear correction, high linearity conversion of input and output.
The software is self-stabilizing to eliminate errors caused by temperature drift and time drift.
The user can set the signal range and signal type through the programmer.
Can be intensively installed.
Note1. (Sn1): Set the corresponding code according to the sensor model.
Note2. (PvL1): Set the zero point value of the first transmission output.
Note3. (PvH1): Set the full point value of the first transmission output.
Note4. (PB1):Used to fine-tune the output zero point.
Note5. (K1):Used to fine-tune the output full point.
Note6. (out1):
The first transmission output type,3 output types can be set:
When out1=1, it is0~10mA or0~2.5V transmission output.
When out1=2, it is4~20mA or1~5V transmission output.
When out1=3, it is0~20mA or0~5V transmission output.
Note7.(InL1) (InH1): Set the minimum and maximum values of the first non-standard input signal only when Sn=16 or 17 millivolt signal or resistance signal input, it needs to be set. With remote transmission pressure gauge0~375Q input
Set as an example: InL1=0,InH1=375
Note9.The second parameter setting is exactly the same as the first parameter setting
Note10. (A--B):
Channel selection:
A--B=0 means two in and two out,
DualA--B=1 means one input and two output single type.
Specifications:
Structure: Small card structure.
Connection: 5mm terminal.
Terminal screw material: Nickel plating on iron.
(Screw allowable torque is less than 0.8N .m)
Case material: Flame Resistant Resin
Isolated: Channel insulation(between input-output-power supply)