The flow sensor mainly consists of a plastic valve body, a water flow rotor assembly, and a Hall sensor.
The product has a lightweight and flexible appearance, small size, and is easy to install. The impeller is internally inlaid with stainless steel beads, which is wear-resistant. Design of lines and isolation from water.
Valve body is made of transparent material to facilitate observation of water flow and rotor conditions. All raw materials meet testing standards.
Working voltage range: 3.5-24V; Load capacity: ≤ 10 mA (DC 5V); Allowable pressure resistance water pressure below 1.75Mpa
Scope of application: Suitable for water heaters, card readers, automatic water dispensers, and other flow metering equipment
وصف
Product parameters:
Basic parameters:
1. Minimum rated operating voltage DC4.5
2. Maximum operating current 15 mA (DC 5V)
3. Operating voltage range 5V-24V
4. Load capacity ≤ 10 mA (DC 5V)
5. Operating temperature range ≤ 80℃
6. Operating humidity range: 35%~90% RH (without frost formation)
7. Allowable pressure resistance water pressure below 1.75Mpa
8. Storage temperature: - 25~+80℃
9. Storage humidity: 25%~95% RH
Technical requirements:
1. Output pulse high level>DC4.5V (input voltage DC5V)
2. Output pulse low level
3. Accuracy flow rate - pulse output) within 1~30L/min ± 1%
4. Output pulse duty ratio 50 ± 10%
5. Output rise time 0.04 μ S
6. Output drop time 0.18 μ S
7. Flow pulse characteristic: horizontal test pulse frequency technique (Hz)=[5.5Q] ± 2% (horizontal test) (Q should flow L/min)
8. Impact resistance: The product is packaged well, and falls freely from a height of 50 cm in X, Y, and Z directions to the concrete surface without abnormality, with an accuracy change of within 10%
9. Insulation resistance: The insulation resistance between the sensor and the copper valve body is above 100MQ. (DC 500V)
10. Heat resistance: Place in an environment of 80 ± 3 ℃ for 48 hours, return to normal temperature for 1-2 hours, and there is no abnormality with an accuracy change of within 10%
11. Cold resistance: Place in an environment of - 20 ± 3℃ for 48 hours, return to normal temperature for 1-2 hours, and there is no abnormality. the accuracy change is within 10%.
Frequency: F=5.5 * Q (L/Min)
Error: ± 2%
Voltage: 3.5-24VDC, current cannot exceed 10mA
Output waveform: square wave
Output 330 pulses after flowing a liter of water
Frequency calculation=constant 5.5 * unit flow rate (L/min) * time (seconds)
Flow range: 1-60L/min