Motors
Power on settings:
Change P-000 to 385 (or 316)
Change P-002 to the corresponding motor code (e.g. 80ST-M02430 corresponds to a parameter of 28, please refer to the Specifications and Adapted Motor section in the corresponding driver model manual)
Change P-036 to 1 (opposite direction) 0 (positive direction) motor direction conversion parameter
Change P-098 to 1 (internal enable) 0 (external enable)
The larger the parameter of P-029 electronic gear ratio, the faster the speed
Long press the confirm button on E-SEF to display DONE saved successfully. After setting all parameters, power off and restart.
overload protection parameters
P-065 (internal forward limit 0-300%) Example: Set parameter 300 to represent 300%
P-066 (internal reverse limit 0-negative 300%) Example: Parameter set to -300 represents -300%
P-070 (Forward overload rate alarm) Example: Setting the parameter to 100 represents
P-070 (Reverse overload rate alarm) Example: Parameter set to -100 represents -100%
T3D startup settings
Change P-036 to 1 (opposite direction) 0 (positive direction) motor direction conversion parameter
Change P-098 to 1 (internal enable) 0 (external enable)
The larger the parameter of P-029 electronic gear ratio, the faster the speed
Long press the confirm button on E-SEF to display DONE saved successfully. After setting all parameters, power off and restart.
==========
Hign-concerned Chemical : None
Power Supply : AC
Model Number : 130ST-M15025
Motor : AC Motor
servo motor kits : 130ST-M15025
Rated voltage : 220V 380V
Frequency : 2500 - 5000 rpm
Rated Moment : 15NM
Output Power : 3.8(Kw)
Matched Motor : 3800W Servo Motors
220v DRIVER : T3DF-L30F-RABF
motor shaft : 22mm with 7mm keyway
Phase : Single-phase
Output shaft : 22mm
keyway : 7mm
communicate : With 485 communication
380v DRIVER : T3A-H25F-RABF