  • YRDIZIXT ADM-4180D 16DI Isolated Digital / 16-channel Switching Acquisition Module MODBUS-RTU RS485 Communication

وصف

Product description
DM-4180D is a 16-channel isolated digital / switching acquisition module, which can be widely used in signal acquisition and monitoring of industrial field equipment. It has 16-channel isolated digital inputs, and 1 ~ 8-channel digital inputs have technical functions. Each channel of DI0 ~ DI7 has a 16-bit counter, which can measure the switching pulses within 200HZ. The communication interface adopts RS-485 interface and supports the standard MODBUS-RTU protocol. It can directly connect with configuration software, PLC, and DCS industrial control touch screen.
Digital input
1. Input channel: 16 switching signals (dry contact) or level signals (wet node)
2. Input polarity: common anode input, can be connected to NPN sensor
3. Input range: high level (number 1): 10V ~ 30V, low level (number 0); 0V ~ 1V
4. Sampling rate: 1MHZ
5. Isolation voltage: 1KV
6. Input count: 8-channel (DI0 ~ DI7) 16-bit (0 ~ 65536) counter, input frequenc is less than 200HZ
Communication Interface
1. Communication protocol: MODBUS-RTU
2. Interface type: Optically isolated RS-485 interface
3. Interface protection: 15KV ESD protection, 1500V isolation protection
4.Baud rate: 1200PBS, 2400PBS, 4800PBS, 9600PBS, 19200PBS, 38400PBS, 57600PBS, 115200PBS
5, check digits: no parity, even parity, odd parity
6. Default parameter: 9600. N. 8.1 (baud rate and parity bit can be modified)
System parameters
1. Module size: 104mm * 72mm * 26mm
2. Installation method: 35 password DIN rail installation
3. Working power: DC9 ~ 30V less than 3 W
Module indicator definition
1. POWER: Power status indicator, steady light indicates normal power supply
2. COMM: RS-485 interface communication instruction, flashing means the module is sending and receiving data
3. DI0 ~ DI15: Digital input indication, when lit, there is input for switching value.
Module register address description
1. 10001 ~ 10016: switch input register address (1X area)
MODBUS register addresses 10001 ~ 10016 are decimal addresses, which means that the hexadecimal address using the 02 function code is 0x0000 ~ 0x000F.
Origin : Mainland China
Certification : CE

منتجات شبيهه


{"error":"\u062e\u0637\u0623","cart_limit":"\u0644\u062f\u064a\u0643 \u0627\u0644\u0643\u062b\u064a\u0631 \u0645\u0646 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0641\u064a \u0633\u0644\u0629 \u0627\u0644\u062a\u0633\u0648\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643.","prod_limit":"\u0644\u0627 \u064a\u0645\u0643\u0646\u0643 \u0625\u0636\u0627\u0641\u0629 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c"}