Measuring range: 1A~100kA, maximum measurable 500kA, bandwidth 1Hz~5kHz
Safe and : No open circuit risk on the secondary side, overload resistant, IP65 protection
Easy installation: Φ12 outer diameter, cable tie fixing, suitable for large cross-section/irregularly shaped conductors, and confined spaces
Low drift: Zero drift 0.05mV, position error ≤±1%, phase error 0.5°
No external integrator required: Can be directly connected to our guide rail/panel instrument
وصف
Model Specifications
Table
Model Total Coil Length Window Size Coil Resistance
SRC-100 410mm 100mm 375(±10)Ω
SRC-150 565mm 150mm 540(±10)Ω
SRC-300 1000mm 300mm 640(±10)Ω
Output Ratio (50Hz)
Calibrated: 333/150/100/50 ±0.5% mV/kA
Uncalibrated: 360/160/105 ±5% mV/kA
Environment & Safety
Operating Temperature: -40℃~80℃, Storage: -50℃~90℃
Insulation Withstand Voltage: Coil 2000V, Signal Line 1000V
Safety Rating: 1000V CAT III, 600V CAT IV, CE certified, compliant with EN 61010-1, EN 61326-1
Material: retardant UL 94 V0, fully shielded for interference suppression
Applications: Power monitoring, harmonic/transient detection, DC ripple testing, laboratory instruments, power analyzers, etc.