product parameters
working voltage :3.0V ~ 5.5V DC( wide voltage compatible, support 3.3V/5V system )
temperature range :
object temperature :-70 ℃ ~ 380 ℃ (resolution 0.02 ℃)
sensor temperature :-40 ℃ ~ 125 ℃ (for al compensation)
accuracy :± 0.5 ℃ (typical value, 0 ℃ ~ 50 ℃ object temperature)
of field of view: 90 °(DCI narrow field version, effective distance 2~5cm)
emissivity :0.95 (default fixed, software adjustable 0.1~1.0)
interface protocol :I²C digital interface (address 0x5A fixed)
response time of : of power consumption of: operating current 1.2mA (typical), standby current 0.5μA
package :TO-39 metal sealed package (anti-electromagnetic interference)
Product main function introduction
MLX90614ESF-DCI module integration Melexis infrared thermopile sensing technology, Output the calibrated surface temperature of the object through I²C (non-contact measurement). Built-in 17-bit ADC and DSP signal processing unit, support Automatic compensation of ambient temperature and emissivity correction.
Product main pin function
VIN: Power input (3.0V ~ 5.5V DC, 100nF decoupling capacitor in parallel);
GND: Power grounding;
SCL : I²C clock line (2.2kΩ pull-up resistor needs to be externally connected to VIN);
SDA :I²C data line (for bidirectional transmission, an external 2.2kΩ pull-up resistor is required to VIN);
PWM: pulse width modulation output (can be configured as temperature alarm signal, open drain structure).