مميزات خاصة

  • Working voltage: DC 24V
  • Output port : 10A relay NO COM NC three ports
  • Relay load: 10A/250VAC; 10A/30VDC
  • Size: 74.4*40.5*19.7MM
  • Weight : 29.2g

وصف

Product Name:DC 24V Multifunction Pulse Counter Trigger Delay Timer Relay Switch Module Simple PLC Board

Package inlcuded:
DC 24V 1 channel Counter Cycle Delay ON/OFF Relay Board

Product Specifications:
Working voltage: DC 24V
Working current: Digital tube OFF (Power-Saving Status): Relay OFF 6MA, Relay ON 35MA
Digital tube ON (Working Status): Relay OFF 29MA, Relay ON 56MA
Three states : Working State, Power-Saving Status, Setting State
Input port : Optocoupler isolation input, compatible with NPN/PNP input (24V switch signal)
Output port : 10A relay NO COM NC three ports
Working mode: F00-F05 single-shot pulse control mode, which is a general delay relay mode
F10-F15 pulse counting control mode, count control relay for input port

Size: 74.4*40.5*19.7MM
Weight : 29.2g
Relay load: 10A/250VAC; 10A/30VDC

Please contact me for detailed instructions.

Product Features:
Delay time 0.1s-9999999.9S(115.7Day), Step 0.1S, Accuracy 0.01S
Pulse count value 0-9999 can be set
F00-F05, F10-F15 12 working modes, there are 8 working modes to set the number of cycles

There are three wiring methods for the trigger signal input terminal:
1. No external signal source required
2. Trigger with NPN source
3. Trigger with PNP signal source

Setup Instructions:
Short press: Press key time is less than 2 seconds;
Long press: Press key time more than 2 seconds;
Status : Working State, Power-Saving Status, Setting State

Factory Setting: Press and hold the ''++'' and ''--'' buttons simultaneously for 3 seconds to restore the Factory Settings and turn off the display of the digital tube. Run the default parameters after power cycle.
Note: After setting the parameters, it must be powered on again.

منتجات شبيهه


{"error":"\u062e\u0637\u0623","cart_limit":"\u0644\u062f\u064a\u0643 \u0627\u0644\u0643\u062b\u064a\u0631 \u0645\u0646 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0641\u064a \u0633\u0644\u0629 \u0627\u0644\u062a\u0633\u0648\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643.","prod_limit":"\u0644\u0627 \u064a\u0645\u0643\u0646\u0643 \u0625\u0636\u0627\u0641\u0629 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c"}