For Murphy digital signal display instrument PV101-C display table PV101-C-M02
The PV101 is a powerful new addition to the MurphyLink product family, providing a window into the monitoring of modern electronically controlled engines and drivetrains.
The P101 is versatile and allows equipment operators to see not only standard engine and driveline operating parameters, but also dynamic and historical fault information. It can display one parameter on one screen or four parameters on one screen. For most common faults displayed in text with code. Extra bright general fault and shutdown fault indicators (amber and red) enhance the alarm function.
product features:
Suitable for electronically controlled engines and other equipment using the J1939 protocol
Can display more than 50 J1939 standard parameters from engine and transmission ECUs
Display dynamic faults and historical faults in text mode, and equipment faults can be seen at a glance
Installation, wiring and equipment are extremely simple and easy to use without programming.
Parameter display:
Engine speed, engine operating hours, fuel consumption rate, system voltage, engine load % at current speed, coolant temperature,
Oil pressure, fuel economy, throttle position, engine intake manifold air temperature, current fuel consumption, transmission oil pressure,
Transmission oil temperature, transmission gear position, dynamic fault codes, historical fault codes (if supported), engine configuration parameters
Specification:
Operating Voltage
Minimum 6.5VDC, Maximum 32VDC
Minimum 8VDC, maximum 32VDC (when PVM instrument is selected)
Reverse Polarity: Can withstand battery reverse polarity indefinitely within the operating temperature range.
environment:
Working temperature: -40-85℃ (-40~185℉)
Storage temperature: -40-85℃ (-40~185℉)
Environmental sealing: IP68, ±5PSI (±34.4kPa)
Power supply working current:
(at 14VDC) minimum 52mA; maximum 300mA
(at 32VDC) up to 1A (when LCD heater is on)
CAN bus: Compliant with SAE J1939
Shell: Polycarbonate, Polyester
RS485 communication interface
User can set Modbus master or Modbus slave
Master active (default) can drive PVA or PVM analog meters
Slave activation provides remote data communication
Impedance input: (user selectable)
Backlight Adjuster: 1000 Ohms, 1/4 Watt
Fuel Level Sensor: 33 ohms (full), 240 ohms (empty)
Shipping Weight (all models): 1 lb (450 g)
Shipping size (all models): 5*6*6 inches (127*152*152mm)
Mounting Fixture: Polyester (PBT)
Connector: Delchi DT06 six-pin series
Mounting Panel Maximum Thickness: 3/8" (9.6mm)