Precise Speed Control: Ensures your generator delivers stable, safe power, perfectly protecting your connected sensitive electronic devices
Durable and Long-Lasting: Manufactured with corrosion-resistant metal components and precision-calibrated;Its robust construction withstands high temperatures, vibrations, and oily environments within the engine compartment, ensuring long-term reliable operation and extending your generator's overall lifespan
Handles Multiple Failure Scenarios: Is your generator experiencing speed instability, excessive or fluctuating voltage, or abnormal shutdowns? These issues often stem from a faulty stock governor. Our replacement kit offers a direct, cost-effective solution for these problems, suitable for diverse applications including home backup power, construction site operations, and RV camping
وصف
Specifications of Engine Interface Module 630-466
The FG Engine Interface Module is a sealed engine mounted module that provideds switching relays for the starter motor solenoid, glow plug and fuel solenoid.
Each of these circuits is protected with individual automative fuses mounted in the module. Individual LED's illuminate when each circuit is energized in addition these LED's greatly aid when fualt finding.
This module is mounted on the engine with anti-vibration mounts and is easily connected to the engine via loom plugs. Use of the FG EIM 630-466 PLUS means that heavy currents such as fuel solenoid power are isolated from the control panel thus enabling individual protection of each of the circuits.
How to Install FG EIM?
Ensure the MPU(Magnetic Pickup) is installed correctly.
Unscrew and pull out the magnetic pickup that is located near the flywheel of the engine
Inspect the magnetic tip and ensure that is it clean and free of debris.
Screw the MPU in until the tip makes contact with the top of the flywheel teeth.
Back out the magnetic pickup 1/2 to 3/4 of a turn.
Turn the ten-turn potentiometer between five to seven turns clockwise or just until you feel a small click-signifying the full
span of the pot.
Start the generator set,you will notice the overspeed calibration LED illuminated.
Slowly turn the potentiometer counter-clockwise until the LED just turns off.
As soon as the LED turns off,start to slowly turn back the potentiometer clockwise just until the led starts to flicker.
Package List:
1 * Engine Interface Module 630-466