WYDDDARY يتحمل جهاز اختبار الوعاء العالي RK2671AM 220 فولت 10 كيلو فولت تيار متردد/تيار مستمر، أدوات اختبار تحمل الجهد الكهربي 100 فولت أمبير، أداة اختبار مقاومة العزل، شاشة LED رقمية، جهاز اختبار Hipot
【10KV AC/DC Testing】Effortlessly perform high-voltage withstand tests with this RK2671AM tester, capable of handling 10KV AC/DC voltages. The environmental temperature is 0~40℃, the relative dumidity≤75%.
【Reliable Safety Features】: Incorporates a 3-hole power supply plug and solid GND connection for enhanced safety, backed by a stable voltage regulator for long-lasting performance.
【LED Display】Clear and easy-to-read high-brightness LED display shows test time, voltage, current and real-time display of breakdown current value and voltage value, ensuring an efficient and accurate testing process.
【Versatile Applications】Designed for versatile usage in various industries, including electrical testing, transformers, meters, motors, cables, and electronics –Complying with the national standard, it has become a necessary pressure resistance test tool for many manufacturers.
【Complete Testing Kit】1×Withstand Voltage Test Equipment; 1×High Voltage Test Bar; 1×Ground Line; 1×Power Cord; 1×Remote Control Test Bar
وصف
Paraments
Model: RK2671AM
Description: Klgital display with remote control
Test Voltage (AC): 0~10KV +/-5%
Test Voltage (DC): 0~10KV +/-5%
Leakage Current (AC): 0~2/20mA +/-5%
Leakage Current (DC): 0~2/10mA +/-5%
Timing (s): 0~99s; Manual control
Pmax: 100VA
Intput Voltage(Power): 220V
Weight: 40lbs
Pre-used Caution
Read the following items carefully before operating RK267 series voltage withstand test instrument
1. Use three-hole power supply plug and insure GND connection well.
2. GND port and power supply GND port should be connected well.
3. Wear insulation glove, stand on insulation mat.
4. Anti-clockwisely circumvolve "V-ADJ" rotary switch to the maximum before turn on test instrument.
5. Before preset all functions, reset instrument.
6. Don't connect test port and test wire when doing test.
7. Don't connect HV output port with shield box or GND wire to avoid instrument damage.
8. Turn off power when accident take place.
9. Examine and repair when Indicator or annunciator is out of function.
10. Operate carefully to avoid hazard when take the remote test.
11. The instrument must be placed on the worktable of conductive materials.
12. The operator can not wear clothes with metal decoration or wear metal accessories.
13. When the tester is in the test conditions, the test line, the test probes, output end, and the test objects are all with high pressure, do not touch!