Ammeters
W3005 Digital Hygrometer For Incubator LED Humidity Controller Sensor Meter Detector Control Switch Hygrostat AC 220V DC 12V 24V
Description:
Model: XH-W3005
Humidity Range: 00%~99%RH
Humidity Control Accuracy: 0.1% RH
Measurement Accuracy: ± 2% RH
Load Power: 12v 120w or 24v 240w or 220v 1500w (depending on your choice)
Output: Max10A
Output Type: Direct output
Sensor length: 1m
Size: 60* 45 * 31 mm
Packing List:1x Humidity Controller + 1x Sensor
Detecting Humidity
Up Button
Down Button
Output Indicator
Item No.
Instructions:
Connect to power supply, diplay indicating humidity.
A. Set the starting humidity: Press the Up button once to show the starting humidity;
Long push the Up button more than 3 seconds until the reading flashing, then push the Up or Down button to set the Starting Humidity Value.
B. Set stop humidity: Press the Down button once to show the stop humidity;
Long push the Down button more than 3 seconds until the reading flashing, then push the Up or Down button to set the Stop Humidity Value.
C. Reset: When the power is on, long press the Up and Down button at the same time for 3 seconds. The reading shows 888, and then the controller automatically jumps to the detected humidity.
Wiring Way
Note:
1. 12V/24VDC W3005 can use the or 12V/24V DC Power Supply.
2. W3005 is Direct Output: The output and input voltage are synchronized.
When the humidity controller is working ( the indicator light is on), the output voltage is the same as input voltage;
When the humidity controller is off (the indicator light is off), the output will do not have voltage.