OX-D69-2058 Digital Multifunction Meter is to display the measured AC voltage, AC current, active power, power factor, frequency, and power/electricity six electric parameters on the same screen of one meter. The display part of the meter adopts colourful high-definition liquid crystal display.
NOTE:Voltage 110V 220V Select AC 40-300V
Voltage 380 450V Select AC 200-450V
Attention
1. Voltage input (green) terminal and current secondary input (blue) terminal wiring can not be connected incorrectly, otherwise the meter will be damaged!
2. In the process of installing the meter, remember not to squeeze the screen of the meter, otherwise there will be garbled/broken code!
4. If you buy more than one instrument to use, the can not be used interchangeably! Because the instrument and the is a pair of calibration] so as not to affect the measurement accuracy!
Main technical indicators
1. Measurement accuracy: 1% ± 2digit
2.Measuring range: AC voltage: AC40.0-300.0V true RMS measurement.
AC current: ACO-99.99A, current display resolution is 0.01A, over 100A when displaying 100.OA
[the rest is 1W
Electrical energy: measurement range is 0-99999kwh, 0-999.99kwh minimum display resolution of 0.01kwh 10000.0-9999.9kwh minimum display resolution of 0.1kwh, 10000.0-99999kwh minimum resolution of 1kwh
Frequency: 45.OHz-65.0Hz Power Factor: 0.00-1.00PF
3.Measuring Speed: 2 times per second
4.External Dimensions: 79*43*48mm
5.Installation Dimensions: 76*39mmVisual Screen Size: 52*26mm
6. Memory function: when the meter is in use in the process of power outages when the meter's cumulative value of power will be self-storage (before the power data preservation).
Operating instructions for use
1. Connect the wiring according to the attached wiring diagram, connect the secondary end of the current (green lead) with the instrument to the blue terminal of the instrument, and pass the measuring circuit lead through the middle hole of the current .
2. Connect the voltage measurement lead to the green terminal of the instrument, then measure the voltage as above and start reading the measurement results.
3. Turn on the power and the instrument displays the measured value.
4. Press and hold the zero button on the front panel of the instrument for 5 seconds to clear the accumulated value of the instrument's power will be cleared.
5.100A hole diameter 15.5mm can meet the national standard 21-25 square mm standard copper wire through the
6. Limit working conditions: working temperature: -10 ~ +50
Working humidity: 10 ~ 80% (no condensation) Working air pressure: 80 ~ 106kPa
Sunlight irradiation: no direct irradiation
==========
Hign-concerned Chemical : None
Dimensions : 79*43*48mm
Accuracy Class : 1%±2digit
Model Number : D69-2058
Display Type :
DIY Supplies : ELECTRICAL
Color : Black
Measuring Speed : 2 times per second
Installation Size : 76*39mm