بحث

بيت / Mersen / دائرة حماية
Mersen AJT AMP-TRAP 2000 SMARTSPOT TIME-DELAY/CLASS J FUSE مع الحد الأقصى للحماية من الدائرة ، 600VAC/500VDC ، 200KA AC/100KA DC ، 200 أمبير ، 1-5/8 "قطر x 5-3/4" in Kuwait

Mersen AJT AMP-TRAP 2000 SMARTSPOT TIME-DELAY/CLASS J FUSE مع الحد الأقصى للحماية من الدائرة ، 600VAC/500VDC ، 200KA AC/100KA DC ، 200 أمبير ، 1-5/8 "قطر x 5-3/4"

KWD 32
KWD 34

ماركة
Mersen
وزن
454 g
1 +

مميزات خاصة

  • Solid state SmartSpot visual blown fuse indicator
  • Time-delay for motor starting and transformer inrush
  • Extremely current-limiting for low peak let-thru current
  • Most current-limiting UL class fuse
  • Recommended for arc flash energy reduction
  • Class J
  • Time Delay Characteristics
  • 600 Vac/500 Vdc
  • 200 Ampere
  • Interrupting Rating 200 Kiloampere (Ac), 100 Kiloampere (Dc)

وصف

Mersen AJT Amp-Trap 2000 SmartSpot time-delay/class J fuse with maximum circuit protection. It provide a visual open fuse indicator. With advanced material technology the AJT fuse provides IEC Type 2 No damage protection to main, feeder, and branch circuits, for all types of loads - yet, they require only half the mounting space needed for 600VAC class RK fuses. AJT's time-delay characteristics are ideal for handling typical motor and transformer inrush currents, while also providing superior current-limiting ability. 300kA interrupting rating - self-certified, UL witnessed tests. Small footprint requires less mounting space and allows smaller, more economical fuse blocks. Easy 2-to-1 selectivity for prevention of nuisance shutdowns. Unique class J dimensions prevent replacement errors. High-visibility orange label gives instant brand recognition. Metal-embossed date and catalog number for traceability and lasting identification. Fiberglass body provides dimensional stability in harsh industrial settings. High-grade silica filler ensures fast arc quenching. Optional EI indicator/switch mount for open fuse indication. Use for motor circuits; mains; feeders; branch circuits; lighting, heating and general loads; transformers; control panels; circuit breaker back-up; bus duct and load centers. Highlights: SmartSpot indicator, time-delay, highly current-limiting, arc flash mitigating, DC ratings, optional mechanical indicator. Approvals: UL listed to standard 248-8 file E2137, DC listed to UL standard 248, CSA certified to standard C22.2 No. 248.8, IEC 269-2-1. UL listed, DC tested to UL standard 248. 600VAC/500VDC voltage rating. 200kA AC/100kA DC IR rating. 200 ampere current rating. Measures 1-5/8-inches diameter by 5-3/4-inches length.
Mersen AJT200 600V 200A Class J Time Delay Fuse, UL Power Fuse, Class J, Time Delay Characteristics, 600 Vac/500 Vdc, 200 Ampere, Interrupting Rating 200 Kiloampere (Ac), 100 Kiloampere (Dc), Blade Terminal, Diameter 1-5/8 Inch, Length 5-3/4 Inch, Approval Ul 198L, Ul 248-8, Csa C22.2, Amp-Trap 2000[R] Brand

منتجات شبيهه


{"error":"\u062e\u0637\u0623","cart_limit":"\u0644\u062f\u064a\u0643 \u0627\u0644\u0643\u062b\u064a\u0631 \u0645\u0646 \u0627\u0644\u0645\u0646\u062a\u062c\u0627\u062a \u0641\u064a \u0633\u0644\u0629 \u0627\u0644\u062a\u0633\u0648\u0642 \u0627\u0644\u062e\u0627\u0635\u0629 \u0628\u0643.","prod_limit":"\u0644\u0627 \u064a\u0645\u0643\u0646\u0643 \u0625\u0636\u0627\u0641\u0629 \u0627\u0644\u0645\u0632\u064a\u062f \u0645\u0646 \u0647\u0630\u0627 \u0627\u0644\u0645\u0646\u062a\u062c"}