9000B high and low voltage clamp ammeter, suitable for high and low voltage leakage current and current measurement below 60kV, range: 0.00mA~1200A, jaw size is Φ48mm
Resolution : 0.01mA; Current clamp uses special alloys, magnetic shielding technology, strong anti-interference ability to ensure the accuracy and stability of the measurement. Automatic Shutdown : Auto Shutdown in 15 minutes or so
Accuracy: ±1%rdg±3dgt(23°C±5°C, 80%r or less); LCD Size : 47mm×28.5mm(with Backlight); Measurement method : Clamp CT, non-contact measurement, integral method;
The ammeter is composed of a high voltage detector and five high-voltage insulated rods. The insulation rod is light, with features such as moisture resistance, high temperature resistance, impact resistance, bending resistance, high insulation, and detachability.
The instrument has functions such as peak hold, data retention, and data storage (group 99). It can also be used as a tester for high and low voltage ratios, that is to measure the high and low voltage currents of the primary and secondary circuits, respectively, and can be calculated by manual calculation. The ratio of high and low pressure.
وصف
Shipping Policy : Battery Not Included During the Shipping
Technical Specifications
Function: High voltage AC current measurement, low voltage AC current, leakage current measurement
Clamp size : Φ48mm
LCD size: 47mm×28.5mm (with backlight)
Range : AC 0.00mA~1200A
Resolution : 0.01mA
Accuracy: ±1%rdg±3dgt(23°C±5°C, 80%r or less)
Data Storage : Group 99
Automatic Shutdown : Auto Shutdown in 15 minutes or so
Working environment: -10°C~40°C; 80% rh below
Storage environment: -10°C~60°C; 70% rh below
Structure : Anti-Drip II Type
Transmission method : Wireless transmission, the maximum distance of straight line transmission is about 30 meters, can penetrate multi-storey building obstacles
No signal indication: "no- -" symbol is displayed dynamically when the receiver does not receive a transmission signal
Interference : Avoid 315MHz, 433MHz co-channel interference
Measurement method : Clamp CT, non-contact measurement, integral method
Frequency : 50Hz, 60Hz Automatic Recognition
Shift : Automatic shifting
Data Hold : Press HOLD key to hold data in test mode, “HOLD” symbol display
Data review : "MR" symbol indicates that data can be read up and down.
Overflow display : Overrange overflow function: "OLA" symbol display
Line voltage: Line test below 60KV (with 5 sections insulation rod operation)
Measurement time : 0.5 seconds/time
Voltage alarm: When the battery voltage is lower than 4.8V, the battery voltage is low and the symbol is displayed
Insulation rod size : outside diameter Φ32mm, 1m/section (5 sections in total)
Insulation strength: AC100kV/rms (Section 5 between insulation rod and high voltage clamp core)
Size: L x W xT: 255mm X76mmX31mm